CLASS II FSP02/04 SafeBox – Solutions for small spaces and SIN119

Henry Williams offers an innovative, integrated solution to the rail industry in the form of its SafeBox Legacy range which is capable of being installed into existing location cases or into our Legacy Connect Case as part of SIN119 power upgrade works.

Key Benefits:  

  • Class II Electrically Insulated Coating
  • Designed to Network Rail Class II Specification NR/L2/SIGELP/27409
  • Tested to IP4X/IP44 and Impact Resistance to IK10
  • Designed for 40 year life
  • Compatible with both Aluminium and Copper cables
  • Most models are fitted with removable or sliding gland plates to aid main cable installation
  • Small footprint for Legacy retrofit use
  • Mount on standard BRS-SM 440 rails or wooden backboard
  • Compatible with existing Legacy and Ring Circuit power supply arrangements
  • Every enclosure factory tested to verify 3KV coating dielectric strength
  • Surge Arrestor (switched/fused) option
  • Provides safe isolation (pad lockable OFF)
  • Includes isolation and fuse protection of functional output supplies
SafeBox Compact C32
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT with 3 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • (Cu) or (Al) Feeder Cables 6 to 120mm².
  • Ring Circuit (FSP01/02).
  • Removable gland plate.
  • Gland plate to terminal distance: 180mm

The above model is also available with:
  –  1 Functional output supply (SafeBox C11 – CAT:  091/019324).
  –  2 Functional output supplies (SafeBox C22 – CAT: 091/019325)

CAT No. 091/019320
SafeBox SIN119/1SW50
  • Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables 2.5(Cu)/6.0(Al) to 50mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 126mm
CAT No. 0091/001915
SafeBox SIN119/2SW50
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 2 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables 2.5(Cu)/6.0(Al) to 50mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm
CAT No. 0091/001916
SafeBox SIN119/1SW50R
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables 2.5(Cu)/6.0(Al) to 50mm².
  • Ring Circuit (FSP02).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm
CAT No. 0091/001917
SafeBox SIN119/1SW95
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 16 to 95mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 126mm
CAT No. 0091/001918
SafeBox SIN119/2SW95
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 2 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 16 to 95mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm
CAT No. 0091/001919
SafeBox SIN119/1SW95R
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 16 to 95mm².
  • Ring Circuit (FSP02).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm
CAT No. 0091/001920
SafeBox SIN119/1SW120
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 35 to 120mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 153mm
CAT No. 0091/001921
SafeBox SIN119/2SW120
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 2 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 35 to 120mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 186mm
CAT No. 0091/001922
SafeBox SIN119/1SW120R
  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 35 to 120mm².
  • Ring Circuit (FSP02).
  • Sliding gland plate.
  • Gland plate to terminal distance: 186mm
CAT No. 0091/001923
SafeBox Mini 21
  •  Smallest footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT with 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • (Cu) or (Al) Feeder Cables up to 50mm².
  • Ring Circuit (FSP01/02).
  • Gland holes to terminal distance: 70mm
PA05/06439